Another evaluation check issue has been brought to our attention. In this case, the issues is related to a Fuel Flowmeter Accuracy Test. The Beta tester has a scenario in which the flow meter was installed a couple of weeks prior to when it became active. Consequently, the begin date/hour for that component in the system component record was later than the reinstallation date/hour recorded in the Fuel Flowmeter Accuracy Test.
The evaluation check FFACC-4 returned a critical level 1 error stating, "The ReinstallationDate/Hour is not equal to the BeginDate/Hour of the component in the System Component record".
The check specification will be modified to allow for entering the correct reinstallation date/hour, and the corrected evaluation check will be included in the next release.
The evaluation check FFACC-4 returned a critical level 1 error stating, "The ReinstallationDate/Hour is not equal to the BeginDate/Hour of the component in the System Component record".
The check specification will be modified to allow for entering the correct reinstallation date/hour, and the corrected evaluation check will be included in the next release.
Labels: Known Issues for Beta B, Known Issues for Beta B Checks
0 Comments: